LAL reagents are primarily used to test for endotoxins in injectable pharmaceuticals, biological products, and medical devices. They are also used in renal dialysis centers and a wide range of other applications.
Gel-Clot Reagent
Multi-test vials – 2ml vials (approx. 100 tests)
The gel-clot test does not require sophisticated capital equipment and software and is the simplest LAL test to implement.| Reference | Product name | Packaging | Category | 
|---|---|---|---|
| G2250-5 | Pyrotell® Multi-test 0.25EU/ml | 5x2ml | Reagent (Lysate) | 
| G2125-5 | Pyrotell® Multi-test 0.125EU/ml | 5x2ml | Reagent (Lysate) | 
| G2006-5 | Pyrotell® Multi-test 0.06EU/ml | 5x2ml | Reagent (Lysate) | 
| G2003-5 | Pyrotell® Multi-test 0.03EU/ml | 5x2ml | Reagent (Lysate) | 
| E005-1 | Escherichia coli 0113:H10 0.5µg/vial | 1 vial | Control Standard Endotoxin | 
Multi-test vials – 5ml vials (approx. 250 tests)
The gel-clot test does not require sophisticated capital equipment and software and is the simplest LAL test to implement.| Reference | Product name | Packaging | Category | 
|---|---|---|---|
| G5250-5 | Pyrotell® Multi-test 0.25EU/ml | 5x5ml | Reagent (Lysate) | 
| G5125-5 | Pyrotell® Multi-test 0.125EU/ml | 5x5ml | Reagent (Lysate) | 
| G5006-5 | Pyrotell® Multi-test 0.06EU/ml | 5x5ml | Reagent (Lysate) | 
| G5003-5 | Pyrotell® Multi-test 0.03EU/ml | 5x5ml | Reagent (Lysate) | 
| E005-1 | Escherichia coli 0113:H10 0.5µg/vial | 1 vial | Control Standard Endotoxin | 
Single-test vials 0.2ml
The gel-clot test does not require sophisticated capital equipment and software and is the simplest LAL test to implement.| Reference | Product name | Packaging | Category | 
|---|---|---|---|
| GS250-5 | Pyrotell® STV 0.25EU/ml | 50×0.2ml | Reagent (Lysate) | 
| GS125-5 | Pyrotell® STV 0.125EU/ml | 50×0.2ml | Reagent (Lysate) | 
| GS006-5 | Pyrotell® STV 0.06EU/ml | 50×0.2ml | Reagent (Lysate) | 
| GS003-5 | Pyrotell® STV 0.03EU/ml | 50×0.2ml | Reagent (Lysate) | 
| E005-1 | Escherichia coli 0113:H10 0.5µg/vial | 1 vial | Control Standard Endotoxin | 
Pyrosate
The Pyrosate kit is developed as an easy-to-use LAL gel-clot test.| Reference | Product name | Packaging | Category | 
|---|---|---|---|
| PSD250-10 | Pyrosate® 0.250EU/ml tubes | 10 tests | Reagent & Control Standard Endotoxin | 
| PSD250-30 | Pyrosate® 0.250EU/ml tubes | 30 tests | Reagent & Control Standard Endotoxin | 
| PSD125-10 | Pyrosate® 0.125EU/ml tubes | 10 tests | Reagent & Control Standard Endotoxin | 
| PSD125-30 | Pyrosate® 0.125EU/ml tubes | 30 tests | Reagent & Control Standard Endotoxin | 
| PSD030-10 | Pyrosate® 0.03EU/ml tubes | 10 tests | Reagent & Control Standard Endotoxin | 
| PSD030-30 | Pyrosate® 0.03EU/ml tubes | 30 tests | Reagent & Control Standard Endotoxin | 
Turbidimetric reagent
| Reference | Product name | Packaging | Category | 
|---|---|---|---|
| T0051-5 | Pyrotell®-T (≅250 tests) | 5x5ml | Reagent (Lysate) | 
| E005-1 | Escherichia coli 0113:H10 0.5µg/vial | 1 vial | Control Standard Endotoxin | 
Chromogenic reagent
Kinetic assays require a Pyros Kinetix Flex instrument (PKFlex) or a kinetic Microtiterplate reader to read the measurements. In case of an end-point assay a PKFlex or a non-kinetic microtiterplate reader can be used.
| Reference | Product name | Packaging | Categories | 
|---|---|---|---|
| C1500-5 | Pyrochrome®with Pyrosol Buffer (≅160 tests) | 5×3.2ml | Reagent (Lysate) | 
| CG1500-5 | Pyrochrome®with Glucashield Buffer (≅160 tests) | 5×3.2ml | Reagent (Lysate) | 
| EC010-5 | Escherichia coli 0113:H10 10ng/vial | 5 vials | Control Standard Endotoxin | 
Recombinant reagent
PyroSmart NextGen™ recombinant Cascade Reagent (rCR) marks the introduction of a new sustainable recombinant LAL reagent technology for Bacterial Endotoxin Testing (BET).
| Reference | Product name | Packaging | Categories | 
|---|---|---|---|
| PNG050-2 | PyroSmart NextGen (approx.100 tests) | 2.8ml/vial | Reagent (Lysate) | 
| EC010-5 | Escherichia coli 0113:H10 10 ng / vial | 5 vials | Control Standard Endotoxin | 
Alternative reagent
Chromo-LAL lysate is lyophilized with substrate reagent and buffers. It is optimized for the kinetic chromogenic LAL test method in microplate readers.
| Reference | Product name | Packaging | Categories | 
|---|---|---|---|
| C0031-5 | Chromo-LAL (approx.150 tests) | 5×3.2ml | Reagent (Lysate) | 
| E0005-1 | Escherichia coli 0113:H10 0.5µg/vial | 1 vial | Control Standard Endotoxin | 
